United States Department of Agriculture
Natural Resources Conservation Service
Georgia Go to Accessibility Information
Skip to Page Content





Georgia Standard Drawings and Worksheets

The following standard drawings are approved for use in Georgia.  All drawings have been revised to meet the International Building Code (IBC) 2006.  Before using any of the standard drawings, the designer should verify that the standard is adaptable to the site and that design limitations are not exceeded.

 The following drawings and worksheets require Adobe Acrobat or Microsoft Excel.

Practice Standard 313 - Waste Storage Facility Size Date
GA-ENG-313A Litter Storage Requirements Worksheet  1.10 MB 3/05
GA-ENG-313A (Example) Litter Storage Requirements Worksheet (Example)  723 KB 3/05
GA-ENG-313B Litter Dry Stack Structure Design Worksheet (Three Walls-One End Open)  1.56 MB 3/05
GA-ENG-313B (Example) Litter Dry Stack Structure Design Worksheet (Example) 723 KB 3/05
GA-ENG-313C Litter Dry Stack Structure Design Worksheet (Two Walls-Both Ends Open)  123 KB 3/05
GA-ENG-313C (Example) Litter Dry Stack Structure Design Worksheet (Example) 1.39 MB 3/05
GA-ENG-313D Litter Storage / Composter Facility Construction Checklist  71.0 KB 3/05
GA-ENG-313E Specification Sheet for Truss Designer 13.0 KB 10/07
GA-ENG-313CS Poultry Manure Stack Facility Construction Specifications 106 KB 3/05
GA-ENG-313OM Poultry Manure Stack Facility Operation & Maintenance Plan 67.9 KB 3/05
GA-ENG-313T1 Poultry Waste Data Table 53.7 KB 1/06
GA-ENG-313-BW1 Block Walls for Dry Litter and Hen Litter Waste Storage Facilities 348 MB 10/06
GA-ENG-313-DS1 Dairy/Swine Scraped Waste Storage Facility  881 KB 12/07
GA-ENG-313-HS1 Hen Litter Stack Facility  897 KB 12/07
GA-ENG-313-HS3 Hen Litter Stack Facility for 110 mph Winds 864 KB 12/07
GA-ENG-313-PS1 Poultry Litter Stack Facility with 6" x 6" Posts Spaced 5' O.C. 801 KB 12/07
GA-ENG-313-PS2 Poultry Litter Stack Facility with 6" x 8" Posts Spaced 8' O.C. 811 MB 12/07
GA-ENG-313-PS3 Poultry Litter Stack Facility for 120 mph Winds 791 KB 12/07
GA-ENG-313-PS4 Poultry Litter Stack Facility for 110 mph Winds 755 KB 12/07
GA-ENG-313-PS5 Poultry Litter Stack Facility (24-Foot Wide) 737 KB 10/07
GA-ENG-313-PS6 Poultry Litter Stack Facility for 110 mph Winds (24-Foot Wide) 762 KB 10/07
GA-ENG 313-WF1 40-Head Winter Feeder 1.84 MB 10/06
GA-ENG 313-WF2 60-Head Winter Feeder 1.84 MB 10/06
GA-ENG 313-WF3 80-Head Winter Feeder 1.84 MB 10/06
GA-ENG 313-WF4 40-Head Winter Feeder for 110 mph Winds 1.86 MB 10/06
GA-ENG 313-WF5 60-Head Winter Feeder for 110 mph Winds 1.86 MB 10/06
GA-ENG 313-WF6 80-Head Winter Feeder for 110 mph Winds 1.86 MB 10/06
Practice Standard 316 - Animal Mortality Facility Size Date
GA-ENG-316A Poultry Litter and Animal Mortality Data Worksheet  75.2 KB 3/05
Practice Standard 317 - Composting Facility Size Date
GA-ENG-317A Dead Bird Composter Sizing Worksheet  768 KB 3/05
GA-ENG-317A (Example) Dead Bird Composter Sizing Worksheet (Example)  461 KB 3/05
GA-ENG-317B Composter Loading Data Worksheet (For Use By Producers)   57.3 KB 3/05
GA-ENG-317-BIN Quick Release Compost Bins 92.1 KB

12/07

GA-ENG-317-C1 Stand Alone Structure with Deep Bins 475 KB 12/07
GA-ENG-317-C2 Stand Alone Structure with Standard Bins 482 KB 12/07
GA-ENG-317-C3 16-Foot Side Shed 682 KB 12/07
GA-ENG-317-C4 Combination Stack / Compost Facility with Four Deep Bins                  (For Use with Stack Facilities with 5-Foot Post Spacing) 335 KB 12/07
GA-ENG-317-C5 Combination Stack / Compost Facility with Four Deep Bins                        (For Use with Stack Facilities with 8-Foot Post Spacing) 324 KB 12/07
GA-ENG-317-C6 Combination Stack / Compost Facility with Standard Bins 248 KB 12/07
GA-ENG 317-C7 Combination Stack / Compost Facility with Four or More Deep Bins 207 KB 12/07
GA-ENG 317-C8 20-Foot Side Shed 734 KB 12/07
GA-ENG 317-C9 16-Foot Stand Alone Structure 473 KB 12/07
Practice Standard 378 - Pond Size Date
GA-ENG-378-PD1 Plan of Farm Pond 4.72 MB 1/09
GA-ENG-378-PD3 Plan of Excavated Farm Pond 672 KB 8/09
GA-ENG-378-PD2 Plan of Siphon Farm Pond 430 KB 1/06
GA-ENG-378A WinPond Design Supplement Worksheet 71.0 KB 1/09
GA-ENG-378B Plunge Pool Calculation Worksheet for Use with Design Note #6 43.0 KB 1/06
Practice Standard 578 - Stream Crossing Size Date
GA-ENG-578-1 Ford Type Stream Crossing 672 KB 4/09
GA-ENG-578-SC1A Rock Design Spreadsheet for GA-ENG-SC1 42.0 KB 4/90
Practice Standard 657 - Wetland Size Date
GA-ENG-657-DP1 Ditch Plug 141 KB 1/06
Practice Standard 712 - Dry Hydrant Size Date
GA-ENG-049 Pond - Dry Hydrant 172 KB 4/90
GA-ENG-050 Stream - Dry Hydrant 145 KB 4/90
Miscellaneous Drawing Files Size Date
GA-ENG 315A Grid in Gray 27.9 KB 6/04
GA-ENG 315B Grid in Orange 27.9 KB 6/04
GA-ENG 315C Grid in Orange with Side Title Block 34.1 KB 6/04
GA-ENG 315D ANSI A Standard Title Block (8.5" x 11") 50.7 KB 04/05
GA-ENG 315E ANSI B Standard Title Block (11" x 17") 55.5 KB 04/05
GA-ENG 315F ANSI D Standard Title Block (22" x 34") 95.3 KB 04/05

For AutoCAD versions of the above listed Adobe Acrobat files contact will.brown@ga.usda.gov.

< Back to Georgia Engineering